Automotive Industry ATOF 32V Series ATOF Medium Blade Fuse Rated 32V 1-40A (Replaces 257 ATO)
Blade Fuses Rated 32V
For the automotive industry, the ATOF fuse has become the original equipment circuit protection standard for foreign and domestic automobiles and trucks.Readily identifiable and easily replaced, this fuse can be specified for a variety of low voltage electronic applications.
Specification
Specification | ATOF® (Tin Plated) |
ATO Ag (Silver Plated) |
Voltage Rating: | 32 VDC | 32 VDC |
Interrupting Rating: | 1000A @ 32 VDC | 1000A @ 32 VDC |
*Component Level Temperature Range: | -40˚C to +105˚C | -40˚C to +125˚C |
**System Level Temperature Range: 105°C and 85°C are typical system level temperature requirements. |
-40˚C to +85˚C | -40˚C to +105˚C |
Terminals: | Sn plated zinc alloy | Ag plated zinc alloy |
Housing Materials | PA66 | PA66 |
Complies with: | SAE J1284,ISO 8820-3 | SAE J1284,ISO 8820-3 |
UL Listed: | File AU1410 | File AU1410 |
CSA Certificated | File No. 29862 | File No. 29862 |
Ordering Information
Part Number | Package Size |
0287xxx.PXCN | 2000 |
0287xxx.U | 500 |
0287xxx.H | 100 |
0287xxx.L | 50 |
ATO® Ag Fuse | |
0287xxx.PXS | 2000 |
Time-Current Characteristics
% of Rating | Current Ratings | Opening Time Min / Max (s) |
100 | 35A & 40A | 360,000 s / – |
110 | 1A-30A | 360,000 s / – |
135 | 1A & 2A 3A-40A |
350 ms / 600 s 0.750 s / 600 s |
160 | 1A-40A | 250 ms / 50 s |
200 | 1A & 2A 3A-40A |
100 ms / 5.0 s 0.150 s / 5.0 s |
350 | 1A & 2A 3A-40A |
20 ms / 500 ms 80 ms / 500 ms |
600 | 1A-30A 35A & 40A |
– / 100 ms – / 150 ms |
Performances Ratings
Part Number | Current Rating(A) | Typ. Voltage Drop (mV) |
Cold Resistance (mΩ) |
I2t (A2s) |
0287001._ | 1 | 176 | 123 | 0.4 |
0287002._ | 2 | 141 | 53.5 | 1.4 |
0287003._ | 3 | 137 | 31.1 | 7.4 |
0287004._ | 4 | 136 | 22.8 | 14 |
0287005._ | 5 | 128 | 17.85 | 26 |
028707.5._ | 7.5 | 116 | 10.91 | 60 |
0287010._ | 10 | 109 | 7.70 | 115 |
0287015._ | 15 | 102 | 4.80 | 340 |
0287020._ | 20 | 98 | 3.38 | 520 |
0287025._ | 25 | 92 | 2.52 | 1080 |
0287030._ | 30 | 84 | 1.97 | 1510 |
0287035._ | 35 | 87 | 1.61 | 2280 |
0287040._ | 40 | 96 | 1.44 | 3310 |
*Component Level Temperature = the maximum ambient temperature that a single fuse will survive. This does not factor-in the heat from a populated fuse box, but does include the heat from the current load with the proper rerating.
**System Level Temperature represents the ambient temperature of the fuse box at a location within the vehicle. The temperature within a populated fuse box (in a given location) will be higher. The limiting factor is the plating. Sn-plating’s temperature limit is ≈130°C, and Ag-plating allows up to 150°C at the terminal interface.