Lighting System 10.1x3.1x3.1 mm Surface Mount Device Ceramic Slow Blow Fuse 1032 250V 3A SEI 003 With Gold Plated
Approval
Recognized Component for Canada and U.S. 500mA~5A
TUV 500mA~5A
Features
Interrupting Rating: 50 amperes at 250V AC
Body material : Ceramic
Terminations: Gold Plated Brass Caps
Tape & Reel: 24mm tape
Packing Specification: EIA RS-481-2
Quantity: 2,500 pcs per reel.
Application: Telecom Equipment System Power, Lighting System
Lead free materials and RoHS compliant
Halogen free (refers to: Br900ppm, Cl900ppm, Br+Cl1500ppm)
Monolithic, multilayer design
High-temperature performance
-55°C to +125°C operating temperature range
Electrical Characteristic
Rate current | 1 In | 2.5 In |
Min. | Max. | |
500mA-5A | 4 hour | 120 sec |
Environmental Specification
Operating Temperature | -55°C to +125°C |
Vibration | MIL-STD-202G, Method 201(10-55 Hz, 0.06 inch, total excursion) |
Salt Spray | MIL-STD-202G, Method 101, Test Condition B (48Hrs) |
Insulation Resistance | MIL-STD-202G, Method 302, Test Condition A |
Resistance to Solder Heat | MIL-STD-202G, Method 210, Test Condition B (10sec, at 260°C) |
Thermal Shock | MIL-STD-202G, Method 107, Test Condition B (-65°C to +125°C) |
Mechanical Dimension(mm)
Ordering information
P/N | Ampere Rating [ In ] |
Voltage Rating ( V ) |
Nominal Resistance Cold Ohms |
Nominal Melting I²t A² Sec |
SEI .500 | 500mA | 250V | 0.5479 | 1.963 |
SEI .750 | 750mA | 0.2600 | 3.375 | |
SEI 001 | 1A | 0.1800 | 11.22 | |
SEI 1.50 | 1.5A | 0.1027 | 14.85 | |
SEI 002 | 2A | 0.0504 | 19.84 | |
SEI 2.50 | 2.5A | 0.0370 | 20.50 | |
SEI 003 | 3A | 0.0280 | 54.00 | |
SEI 3.50 | 3.5A | 0.0199 | 57.82 | |
SEI 004 | 4A | 0.0158 | 125.6 | |
SEI 005 | 5A | 0.0120 | 185.0 |
Selecting Surface-mount Fuses
Fuse selection seems straightforward, in that, you pick one which has a current rating just a bit higher than your worstcase system operating current. Unfortunately, it’s not that simple. There are derating considerations for operating current and application temperature. Turn-on and other system operations (like processor speed changes or motor start up) cause current surges or spikes that also require consideration when selecting a fuse. So selecting the right fuse for your application is not as simple as knowing the nominal current drawn by the system.
Benefits
• High inrush current withstanding capability
• Ceramic Monolithic structure
• Silver fusing element and silver termination with nickel and tin plating
• Excellent temperature stability
• Strong arc suppression characteristics