Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap

1000 Pieces
MOQ
Negotiable
Price
Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap
Features Gallery Product Description Request A Quote
Features
Specifications
Fuse Type: Ceramic Tube Fuse
Current Rating: 2.5A
Voltage Rating: 250V
Fuse Speed: Fast Blow
Fuse Size: 3.6 Mm X 10 Mm
Mounting Style: Board Mount
Standard: UL 248 -1 / -14
UL File Number: E340427
High Light:

ceramic cartridge fuse

,

ceramic thermal fuse

Basic Infomation
Place of Origin: Dongguan City
Brand Name: AOLITTEL
Certification: UL,cUL
Model Number: HFP1125A
Payment & Shipping Terms
Packaging Details: Bulk,500pcs per bag,20Kpcs per carton ,12kg per carton .
Delivery Time: 7-10 Days
Payment Terms: T/T,Paypal
Supply Ability: 100,000,000 Pieces Per Month
Product Description

 

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap

 

 

Description


Aolittel HFP fast-acting 3.6 x 10mm axial-leaded fuse constructed with ceramic tube and one-piece nickel-plated endcaps featuring tinned copper axial leads. Small 3.6 x 10mm size offers more design flexibility by doing away with conventional over-capping while providing higher I2t values.

 

___________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________

 

 

Operating Characteristics

 

% of Ampere Rating(In)

Blowing Time

100% * In 4 hours Mi
200% * In 60 sec Max

 

 

Certifications

 

Voltage Rating

Agency

Ampere Range

Agency File Number

125V/250V UL 250mA ~ 5A E340427(JDYX)
C-UL 250mA ~ 5A E340427( JDYX7)

 

 

Specification

 

Part

No.

Ampere

Rating

Voltage

Rating

Breaking

Capacity

I2TMelting

Integral(A2.S)

Agency Approvals

UL cUL

 

PSE

HFP 0100A/B 100mA 250V/125V 50A@125V/250VAC 0.0015
HFP 0125A/B 125mA 250V/125V 50A@125V/250VAC 0.0025
HFP 0160A/B 160mA 250V/125V 50A@125V/250VAC 0.0042
HFP 0200A/B 200mA 250V/125V 50A@125V/250VAC 0.0065
HFP 0250A/B 250mA 250V/125V 50A@125V/250VAC 0.010
HFP 0300A/B 300mA 250V/125V 50A@125V/250VAC 0.018
HFP 0315A/B 315mA 250V/125V 50A@125V/250VAC 0.020
HFP 0350A/B 350mA 250V/125V 50A@125V/250VAC 0.025
HFP 0400A/B 400mA 250V/125V 50A@125V/250VAC 0.035
HFP 0500A/B 500mA 250V/125V 50A@125V/250VAC 0.060
HFP 0630A/B 630mA 250V/125V 50A@125V/250VAC 0.150
HFP 0750A/B 750mA 250V/125V 50A@125V/250VAC 0.350
HFP 0800A/B 800mA 250V/125V 50A@125V/250VAC 0.5
HFP 1100A/B 1A 250V/125V 50A@125V/250VAC 0.6
HFP 1125A/B 1.25A 250V/125V 50A@125V/250VAC 1.2
HFP 1150A/B 1.5A 250V/125V 50A@125V/250VAC 1.6
HFP 1160A/B 1.6A 250V/125V 50A@125V/250VAC 1.8
HFP 1200A/B 2A 250V/125V 50A@125V/250VAC 2.4
HFP 1250A/B 2.5A 250V/125V 50A@125V/250VAC 3.2
HFP 1300A/B 3A 250V/125V 50A@125V/250VAC 6.0
HFP 1315A/B 3.15A 250V/125V 50A@125V/250VAC 7.0
HFP 1350A/B 3.5A 250V/125V 50A@125V/250VAC 7.5
HFP 1400A/B 4A 250V/125V 50A@125V/250VAC 8.0
HFP 1500A/B 5A 250V/125V 50A@125V/250VAC 15
HFP 1600A/B 6A 250V/125V 50A@125V/250VAC 24
HFP 1630A/B 6.3A 250V/125V 50A@125V/250VAC 28
HFP 1700A/B 7A 250V/125V 50A@125V/250VAC 36
HFP 1800A/B 8A 250V/125V 50A@125V/250VAC 38
HFP 2100A/B 10A 250V/125V 50A@125V/250VAC 42
HFP 2150A/B 15A 250V/125V 50A@125V/250VAC 45

 

 

Dimension  (mm)

 

                       Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 1

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 2

NO.

Part Name

Material

1

Cap

Nickel Plated Brass

2

Body

Non-Transparent Ceramic Tube

3

Fuse element

Alloy

4

Lead wire

Tin Plated Copper

 

 

Features


• Single cap, axial leaded, fast-acting fuse
• 3.6 x 10mm physical size
• Ceramic tube, nickel-plated brass endcap construction
• Tinned copper axial leads
• RoHS complaint, lead-free and halogen free
• Designed to UL/CSA 248 Standard
• Fast Acting, Ceramic body fuse in a compact package
• Available in ratings of 0.10 to 15 Amperes

 

 

Average Time Current Curves

 

TIME IN SECONDS

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 3

CURRENT IN AMPERES

 

 

Temperature Rerating Curve

 

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 4

 

 

Installation Recommendations

 

A: Propose installation way as following picture.

 

a.

Horizontal installation

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 5
b.

Vertical installation

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 6

Recommended Soldering Parameters

  • Wave Parameters:

Solder Pot Temperature: 260℃ Max

Solder Dwell Time: 2~5s

  • Hand-Solder Parameters:

Solder Iron Temperature: 350±5℃

Heating Time: 5s Max

 

 

 

Why should the DCR of a fuse be measured at a load of no more than 10% and an ambient temperature of 25°C ?

 

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 7

The internal resistance of a fuse is an index reflecting its consumed power in the circuit. The higher the resistance, the more power consumed. For fuses, two parameters can be used to check this index: voltage drop or cold resistance.

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 8

Voltage drop: the voltage drop reading after the fusing element reaches thermal balance under rated current. To measure it, apply rated current to the fuse and wait until the reading is stable. It may take a few minutes. It is a little inconvenient and time-consuming.

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 9

Cold resistance: the reading of cold resistance basically under no load condition, easy and fast.

Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap 10

Therefore, the cold resistance method is always preferred for fuse check. The load of less than or equal to 10% means basically no load or heating condition, so there will be no thermal balance process, while the ambient temperature itself has a certain effect on fuse performance. All performance indexes of a fuse are parameters in ordinary atmospheric condition, i.e. 25°C. The cold resistance of a fuse, if not measured under the above-mentioned conditions, may not be accurate.