August 26, 2024
It will be less than R1max for the device.
Example - JK600 Series Electrical characteristics(25℃)
Model |
Ihold(A) |
Itrip(mA) |
Vmax interrupt(V) |
Imax(A) |
Pd max(W) |
Maximum Time to Trip |
Resistance(Ω) |
|
Current(A) |
Time(S) |
Rmin- Rmax |
||||||
JK600-110U |
0.11 |
0.22 |
600 |
3 |
1.0 |
1.0 |
8 |
6-16 |
JK600-150U |
0.15 |
0.30 |
600 |
3 |
1.0 |
1.0 |
9 |
5-14 |
JK600-160U |
0.16 |
0.32 |
600 |
3 |
1.0 |
1.0 |
10 |
4-12 |
IH=Hold current:maximumcurrent at which the device will not trip at 25℃ still air.
IT=Trip current:minimumcurrent at which the device will nalways at 25℃ still air.
Vmax=Maximum voltagedevice can withstand without damage at rated current.
Imax=Maximum faultcurrent device can withstand tithout damage at rated voltage.
Ttrip=Maximum time totrip(s) at assigned current.
Pd=Typical powerdissipation:typical amount of power dissipated by the decice when in state airenvironment.
Rmin=Minimum deviceresistance at 25℃ prior to tripping.
Rmax=Maximum deviceresistance at 25℃ prior to tripping.