6125 2410 1808 Wire In Air Time Delay Suface Mount Fuse 250V 2A Slow Blow Lead Gold Plated

1000PCS
MOQ
USD 0.04 to 0.06 Per Pieces
Price
6125 2410 1808 Wire In Air Time Delay Suface Mount Fuse 250V 2A Slow Blow Lead Gold Plated
Features Gallery Product Description Request A Quote
Features
Specifications
Type: Wire In Air Time Delay SMD Fuse 250V 2A
Dimension: 6.1*2.5mm(6125/2410/1808)
P/N: SET1200
Ampere Rating: 2A
Volt. Rating: 250Vac
Unit Weight: 0.12 Gram
End Cap: Au Plated Brass Cap
Body: Non-Transparent Square Ceramic Tube
Fuse Element: Cu-Ag Alloy Wire
Operating Temperature: -55°C To 125°C
Agent: UL,CUL,ROHS
Packaging: 1000 Pieces Of Smd Fuses On 12mm Tape-and-reel On A 7 Inch (177mm) Reel Per EIA Standard 481
High Light:

surface mount chip fuse

,

surface mount thermal fuse

Basic Infomation
Place of Origin: Dongguan,Guangdong,China
Brand Name: Aolittel
Certification: UL,CUL,ROHS
Model Number: SET1200
Payment & Shipping Terms
Packaging Details: Tape in reel ; 1,000 pcs in 7 inches dia. reel, 12mm wide tape, EIA Standard 481
Delivery Time: 7 Workdays
Payment Terms: T/T, Western Union, MoneyGram,Paypal
Supply Ability: 5,000,000PCS Per Week
Product Description

 

6125 2410 1808 Wire In Air Time Delay Suface Mount Fuse 250V 2A

 

 

Overview

 

Ao littel surface mount fuses available for addressing a broad range of overcurrent protection applications. Helping to prevent costly damage and promote a safe environment for electronic and electrical equipment, our single-use chip fuses provide performance stability to support applications with current ratings from .5A up to 20A.

 

______________________________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________


Ao littel also offers the telecom FT600 fuse for telecommunications applications. This telecom fuse helps comply with North American overcurrent protection requirements,including Telcordia, GR-1089, TIA-968-A (formerly FCC Part 68), and UL60950 3rd edition

 

The multi-layer design 2410(6125) is a Wire-In-Air SMD Fuse which is very suitable for secondary level over current protection applications.
Compared our straight wire element design 2410SFV fuses with normal corrugating wire design fuse. The straight wire element in air performs consistent fusing and cutting
characteristics together with excellent inrush current withstanding capability.
Introduced PCB assembly technology into 2410 fuses design and manufacture, we achieved on lead free completely and no end cap falling off risk comparing with traditional ceramic body with end cap fuse.

 

Ao littel Surface Mount Fuse Family Member
No. Size Blow Voltage Seires
1 0603 Fast Blow 32V 06.000
2 0603 Time Delay 32V 06.100
3 1206 Fast Blow 32V 12.000
4 1206 Time Delay 32V 12.100
5 6125 Time Delay 250V SET
6 6125 Fast Blow 250V SEF
7 2410 Fast Blow 125V SFE
8 2410 Time Delay 125V STE
9 1808 Fast Blow 300V SSF
10 1808 Time Delay 300V SST
9 1032 Time Delay 125V R1032
10 1032 Fast Blow 125V R1032

 

6125 2410 1808 Wire In Air Time Delay Suface Mount Fuse 250V 2A Slow Blow Lead Gold Plated 1


 

Benefits

 

• Very fast acting at 200% overload current level
• Excellent inrush current withstanding capability
• High reliability and resilience
• Strong arc suppression characteristics
• Copper terminal with nickel and tin plated

 

 

Product features

• Time-delay surface mount fuse with Small 2410 Footprint
• Satisfies the EIA/IS-722 Standard
• Solder immersion compatible
• 250V Voltage Rating (200mA to 30A)
• High Interrupting Ratings
• Designed in accordance with IEC 60127-4 Universal Modular Fuse requirement
• Wide Operating temperature range of -55°C to 125°C
• IEC 61000-4-5 2 ed. Surge Immunity Test Compliant (1.2 x 50us/8x20us combination wave 500V/250A for <25W Lamp Category) – 3A and above ampere rating only

• Halogen free, RoHS compliant and 100% lead-free
• Copper or copper alloy composite fuse link

 

 

Application

 

• Industrial equipment
• LCD/PDP TV
• Backlight inverter 
• Power supplier
• Telecom system
• Networking
• Game systems
• White goods
• Automotive

 

 

Shape and Dimensions (mm)

 

6125 2410 1808 Wire In Air Time Delay Suface Mount Fuse 250V 2A Slow Blow Lead Gold Plated 2

 

 

Specification

 

Part No. Ampere Rating Voltage Rating Breaking Capacity Nominal Cold Resistance (Ohms) I2TMelting Integral(A2.S) Agency Approvals
UL CUL
SET0200 200mA 250VAC 50A@300VAC 50A@250VAC 200A@125VAC 0.92 0.125
SET0250 250mA 0.86 0.145
SET0300 300mA 0.62 0.162
SET0315 315mA 0.55 0.189
SET0375 375mA 0.47 0.2
SET0400 400mA 0.38 0.238
SET0500 500mA 0.32 0.275
SET0600 600mA 0.285 0.47
SET0630 630mA 0.256 0.566
SET0700 700mA 0.208 0.805
SET0750 750mA 0.175 1.24
SET0800 800mA 0.155 1.88
SET1100 1A 0.148 3.5
SET1125 1.25A 0.102 4.76
SET1150 1.5A 0.085 6.305
SET1160 1.6A 0.075 6.505
SET1200 2A 0.044 8.95
SET1250 2.5A 0.043 16.025
SET1300 3A 0.033 21.56
SET1315 3.15A 0.029 22.75
SET1350 3.5A 0.027 27.05
SET1400 4A 0.025 31.808
SET1500 5A 0.019 40.25
SET1600 6A 0.018 67.245
SET1630 6.3A 0.017 73.55
SET1700 7A 0.015 76.28
SET1800 8A 80.75
SET2100 10A 0.014 110.38
SET2120 12A 0.013 158.08
SET2150 15A 0.012 160.68
SET2200 20A 166.58
SET2300 30A 0.011 170.56
  • These part no. cold resistance and I2t value are pending due to fuse elements shall be customized;
  • DC Cold Resistance are measured at <10% of rated current in ambient temperature of 25℃;
  • Typical Pre-arching I2t are calculated at 10*In Current or 8ms;
  • Min Interrupting Rating: 1.35*In.

 

 

Product Characteristics

 

NO.

Item

Content

Reference standards

1

Product Marking

Brand, Ampere Rating Ao littel marking standards
2

Operating Temperature

-55°C to 125°C IEC60068-2-1/2
3

Solderability

T=240°C±5°C , t=3sec±0.5sec, Coverage≥95% MIL-STD-202, Method 208
4

Resistance to Soldering Heat

10 sec at 260°C MIL-STD-202, Method 210, Test condition B
5

Insulation Resistance (after Opening)

10,000 ohms minimum MIL-STD-202, Method 302, Test Condition A
6

Thermal Shock

5 cycles, -65°C / +125°C, 15 minutes at each extreme MIL-STD-202, Method 107, Test Condition B
7

Mechanical Shock

100G’s peak for 6 milliseconds, 3cycles MIL-STD-202, Method 213, Test I
8

Vibration

0.03”amplitude, 10-55 Hz in 1 min. 2hrs each XYZ=6hrs MIL-STD-202, Method 201
9

Moisture Resistance

10 cycles MIL-STD-202, Method 106
10

Salt Spray

5% salt solution, 48hrs MIL-STD-202, Method 101, Test Condition B

 

 

Fusing Characteristics

 

% of Ampere Rating(In) Fusing Time
100% * In 4 hours Min.
200% * In 120 sec Max.
1000% * In 10ms Min .

 

 

Packaging 

 

Tape in reel ; 1,000 pcs in 7 inches dia. reel, 12mm wide tape, EIA Standard 481

 

 

Surface Mount Fuse Selection Flowchart

 

However, the basic considerations for fuse selection are shown in the flowchart presented in Figure 6. Following this flow chart
will help you select a fuse best suited for your application conditions.

6125 2410 1808 Wire In Air Time Delay Suface Mount Fuse 250V 2A Slow Blow Lead Gold Plated 3

 

Step 1 – Determine Steady State Fuse Current Rating 

 

Apply Standard Steady State Derating (75%) [Ifuse ≥ Isys/0.75]  ⇒ Apply Temperature Derating [Ifuse ≥ Isys/0.75/Ktemp] ⇒ Steady State Fuse Current Rating ⇒ Step 2 –Determine Pulse Waveform by Calculating I2t ⇒  Step 3 –Apply Pulse Cycle Derating     ⇒   Step 4 –Apply Pulse Temperature
Derating     ⇒  Step 5 – Apply Derating for Variance in the Circuit  ⇒  Step 6 – Select Fuse Current
Rating for Pulse Environment ⇒ Step 7 – Select Fuse Current Rating (use higher value between Step 1 and Step 6)  ⇒  Step 8 – Check Voltage Rating  

 

 

Selecting Surface Mount Fuses

 

SMD Fuse selection seems straightforward, in that, you pick one which has a current rating just a bit higher than your worstcase system operating current. Unfortunately, it’s not that simple. There are derating considerations for operating current and application temperature. Turn-on and other system operations (like processor speed changes or motor start up) cause current surges or spikes that also require consideration when selecting a fuse. So selecting the right fuse for your application is not as simple as knowing the nominal current drawn by the system.

 

 

Surface Mount Fuse Temperature Derating Comparision

 

A SMD fuse is a temperature sensitive device. Therefore, operating temperature will have an effect on fuse performance and lifetime.Operating temperature should be taken into consideration when selecting the fuse current rating. The Thermal Derating Curve for surface mount fuses is presented in below Figure . Use it to determine the derating percentage based on operating temperature and apply it to the derated system current.

 

6125 2410 1808 Wire In Air Time Delay Suface Mount Fuse 250V 2A Slow Blow Lead Gold Plated 4

 

 

Recommended Products
Get in touch with us
Tel : 18128566098
Fax : 86-769-38935409
Characters Remaining(20/3000)